Dzień dobry. Dostałem ciekawy komunikat po ponownym uruchomieniu zreplikowanego węzła "Log Name: xxxxxxxxxxxxxxx/xxxxxxxxxxxx
Source: xxxxxxxxxxxxxxxxxxxxx
Date: 7/21/2017 14:50:38 AM
Event ID: 4004
Task Category: (7)
Level: Warning
Keywords: (256)
User: SYSTEM
Computer: xxxxxxxxxxxxxxxxx
Description:
Failed to establish a connection to a remote computer.
RemoteComputerName: xxxxxxxxxxxx
LocalReplicationGroupName: xxxxxxxxx
LocalReplicationGroupId: {xxxxxxxx-xxxxx-xxxxxx-xxxxxxx-xxxxxxxxxxxx}
RemoteReplicationGroupName: xxxxx
RemoteReplicationGroupId: {xxxxxxx-xxxxx-xxxx-xxxx-xxxxxxxxxxxx}
ReplicaSetId: {00000000-0000-0000-0000-000000000000}
RemoteShareName:{xxxxxxxxx-xxxxx-xxxx-xxxxxb-xxxxxxxxxx}.{00000000-0000-0000-0000-000000000000}
Status: {Access Denied}
A process has requested access to an object, but has not been granted those access rights.
Guidance: Possible causes include network failures, share creation failures for the remote replication group, or firewall settings. Make sure SMB traffic is allowed and there are no connectivity issues between the local computer and the remote computer. You should expect this event when suspending replication or removing a replication partnership. Nie wiem jak ten problem rozwiązać.
Odpowiedzi: 1
Może z samą usługą Replika magazynu coś się podziało, spróbuj ją zresetować.
-
Problem rozwiązany, dzięki za uwagę.
Czy macierz jest w pełni sprawna ?
Tak z nią nie było problemu do momentu chwilowego wyłączenia, po ponownym uruchomieniu jest problem z repliką magazynu.
Wybierz opcję autoryzacji